The KET-CGT-000 series of turbine meters are optimally suited for measuring of non-fiscal gas flow rates.
The characteristic of these meters is represented by the interchangeability of the cartridge internal, in which are integrated turbine, bearings and transmission gears, in agreement to standard EN 12261.
Protection Range | IP67 |
Operative Temperature | -25 ÷ +65 °C |
Channels | Pulse |
Principle of Operation | Gas velocity measurement |
Max Project Pressure | 20 bar |
Precision | Qmin = Q < Qt ± 3% & Qt = Q = Qmax ± 1,5% |
Flanged Connections | PN 16 o ANSI 150 |
Calibre | G 40 ÷ 650 |
Tube Diameter | Ø 50 ÷ 100 mm |
Standard Flow Direction | Horizontal (high - low on request) |
Lubrication Pump | Yes |
Top | With mechanical totaliser with dual pulse emitter BF |
Referends Standard | OIML R6, OIML R32, EN12261, EEC |
Codice | Calibre | Tube Diameter | Range mc/h | Wheelbase |
---|---|---|---|---|
KET-CGT-040.50 | G 40 | DN 50 (2”) | 13 ÷ 65 | 150 |
KET-CGT-065.50 | G 65 | DN 50 (2”) | 10 ÷ 100 | 150 |
KET-CGT-100.50 | G 100 | DN 50 (2”) | 16 ÷ 160 | 150 |
KET-CGT-100.80 | G 100 | DN 80 (3”) | 16 ÷ 160 | 120 |
KET-CGT-160.80 | G 160 | DN 80 (3”) | 25 ÷ 250 | 120 |
KET-CGT-160.100 | G 160 | DN 100 (4”) | 25 ÷ 250 | 150 |
KET-CGT-250.80 | G 250 | DN 80 (3”) | 20 ÷ 400 | 150 |
KET-CGT-250.100 | G 250 | DN 100 (4”) | 20 ÷ 400 | 150 |
KET-CGT-400.80 | G 400 | DN 80 (3”) | 32 ÷ 650 | 150 |
KET-CGT-400.100 | G 400 | DN 100 (4”) | 32 ÷ 650 | 150 |
KET-CGT-650.100 | G 650 | DN 100 (4”) | 50 ÷ 1000 | 150 |