The KET-MPV-100.000 offers many advantages for flow measurement, including easy installation with flanged or wafer connections, with wide measuring range and very low power consumption (12/24 VDC).
In addition, vortex flow meters are unique in that they are suitable for liquids, gases, steam and corrosive applications. They measure the velocity of the fluid using an operating principle called the Von Kármán effect.
It has a large display to simultaneously display totalized volume, energy, instantaneous flow, and if equipped with probes, even temperatures and pressures.
The KET-MPV-100.000 is equipped with a wide range of communication interfaces, integrating with the X-Monitor network.
Protection Range | IP65 |
Operative Temperature | -10 ÷ +55 °C |
Relative Humidity | MAX 90% not condensing |
Supply Voltage | '+12/24 VDC; Display: Integral 3.2 V Lithium Battery or +24 VDC or 230 VAC |
Connectors types | ISO M20×1.5 Female |
Supported Protocols | ModBUS RTU with transmission distance =500 m |
Communication Rate | Max 115 Kbps |
Channels | Pulse signal |
Voltage Output | Low Level: =1 V; High Level: =6 V |
Output Type | 4 to 20 mA DC current signal |
Measure Range | Liquid: 1.6 ÷ 1800 m³/h; Gas: 10 ÷ 11000 m³/h; Steam: 9.6 ÷ 93480 Kg/h |
Accuracy | Liquid: ±1.0%; Gas: ±1.5%; Steam: ±1.5% |
Fluid Temperature | Standard: -20 °C ÷ +70 °C |
Fluid Pressure | The pressure of the supports is limited according to the size of the flange |
Tube Diameter | Ø 25 ÷ 300 mm |
Flanged Connections | Max PN 16 |
Material | AISI316 and aluminium alloy |
Codice | Tube Diameter |
---|---|
KET-MPV-100.025 | DN 25 (1”) |
KET-MPV-100.040 | DN 40 (1½) |
KET-MPV-100.050 | DN 50 (2”) |
KET-MPV-100.065 | DN 65 (2 1/2”) |
KET-MPV-100.080 | DN 80 (3”) |
KET-MPV-100.100 | DN 100 (4”) |
KET-MPV-100.125 | DN 125 (5”) |
KET-MPV-100.150 | DN 150 (6”) |
KET-MPV-100.200 | DN 200 (8”) |
KET-MPV-100.250 | DN 250 (10”) |
KET-MPV-100.300 | DN 300 (12”) |